Appendix, Codes – Lenze ECSCExxx Power supply module User Manual

Page 140

Advertising
background image

Appendix

Codes

12

l

140

EDBCSXE040 EN 7.0

Parameter

C0384

Designation

Response − CAN node guarding

Data type: INTEGER_32

Index: 24191

dec

= 5E7F

hex

Response to a "Life Guarding Event"if no node guarding telegram has been received during "Node Life Time"
(C0382 x C0383).

l

When C0382 = 0 or C0383 = 0, the monitoring function is not active (no node guarding fault message is
enabled).

l

Only relevant if C0352 = 2.

^ 92
Selection list

(Lenze setting printed in bold)

Information

0 TRIP

1 Message

2 Warning

3 Off

Parameter

C0390

Name

Configuration diagnostics PDO via CAN

Data type: INTEGER_32

Index: 24185

dec

= 5E79

hex

Via C0390/1 ... 8 a diagnostics PDO (8 bytes) can be parameterised, which can be sent via CAN2_OUT.

l

The 8 bytes can be assigned with variables for advanced diagnostics of the mains conditions and the internal
state machine (mapping).

l

In C0391 the assignment in percent (0 ... 100 %) of the 8 bytes of the PDO is shown.

Conditions for sending the diagnostics PDO:
The CAN bus is "Operational" and the cycle time for CAN2_OUT is > 0 ms (C0356/2).

Possible settings

C390/x = 0 Not assigned [0 bytes]

C390/x = 1 Voltage V

L1L2

[2 bytes]

C390/x = 2 Voltage V

L2L3

[2 bytes]

C390/x = 3 Counter of the zero crossings per second (frequency measurement of V

L1L2

) [2 bytes]

C390/x = 4 Mains synchronisation n−times outside the limits (evaluation of V

sd

and V

sq

) [1 byte]

C390/x = 5 Internal status bits [1 byte]

C390/x = 6 Transformed voltage component V

sd

[2 bytes]

C390/x = 7 Transformed voltage component V

sq

[2 bytes]

C390/x = 8 Internal error bits [2 bytes]

Subcodes

Information

C0390/1

Depending on the byte size of the variables selected, it
may happen that the variables in the last subcodes do
not become effective anymore.

^ 113

...

C0390/8

Parameter

C0391

Designation

Assignment of diagnostics PDO in percent

Data type: INTEGER_32

Index: 24184

dec

= 5E78

hex

Display of the assignment of the 8 bytes of the diagnostics PDO (CAN2_OUT) in percent

^ 113
Display range

(min. value | unit | max. value)

0

%

100