A171, A172, A173 – Rockwell Automation 22C PowerFlex 400 AC Drive FRN 1.xx - 7.xx User Manual

Page 102: Advanced program group (continued)

Advertising
background image

3-44

Programming and Parameters

PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P

Advanced Program Group (continued)

A171 [Start Boost]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A170

,

A172

,

A173

,

A174

Sets the boost voltage (% of

P031

[Motor NP Volts]) and redefines the Volts per Hz curve when A170

[Boost Select] = 0 “Custom V/Hz”.

Values

Default:

2.5%

Min/Max:

0.0/25.0%

Display:

1.1%

Frequency

Voltage

A173 [Break Frequency]

P032 [Motor NP Hertz]

P035 [Maximum Freq]

A171 [Start Boost]

P031 [Motor NP Volts]

A174 [Maximum Voltage]

A172 [Break Voltage]

A034 [Minimum Freq]

A172 [Break Voltage]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A170

,

A171

,

A173

,

A174

Sets the break voltage applied at the break frequency when A170 [Boost Select] = 0 “Custom V/Hz”.

Values

Default:

25.0%

Min/Max:

0.0/100.0%

Display:

0.1%

A173 [Break Frequency]

Related Parameter(s):

P031

,

P032

,

P034

,

P035

,

A170

,

A171

,

A172

,

A174

Sets the frequency where break frequency is applied when A170 [Boost Select] = 0 “Custom V/Hz”.

Values

Default:

15.0 Hz

Min/Max:

0.0/320.0 Hz

Display:

0.1 Hz