Advanced Program Group (continued)

A174 [Maximum Voltage]

Related Parameter(s):

b004

,

A171

,

A172

,

A173

Sets the highest voltage the drive will output.

Values

Default:

Drive Rated Volts

Min/Max:

20/Drive Rated Volts

Display:

1 VAC

A175 [Slip Hertz @ FLA]

Related Parameter(s):

P033

Compensates for the inherent slip in an induction motor. This frequency is added to the commanded
output frequency based on motor current.

Values

Default:

2.0 Hz

Min/Max:

0.0/10.0 Hz

Display:

0.1 Hz

A176 [DC Brake Time]

Related Parameter(s):

P037

,

A177

Sets the length of time that DC brake current is “injected” into the motor when

P037

[Stop Mode] is set

to either 4 “Ramp” or 6 “DC Brake”. Refer to parameter

A177

[DC Brake Level].

Values

Default:

0.0 Secs

Min/Max:

0.0/99.9 Secs (A setting of 99.9 = Continuous)

Display:

0.1 Secs

A177 [DC Brake Level]

Related Parameter(s):

P037

,

T051

-

T054

,

A176

,

A178

Defines the maximum DC brake current, in amps, applied to the motor.

Values

Default:

Drive Rated Amps

×

0.05

Min/Max:

0.0/(Drive Rated Amps

×

1.5)

Display:

0.1 Amps

DC Injection Braking Mode

V

olts/S

p

eed

Voltage

Time

Stop Command

Speed

[DC Brake Level]

[DC Brake Time]

V

olts/S

p

eed

Ramp-to-Stop Mode

Time

Stop Command

[DC Brake Level]

[DC Brake Time]

Voltage

Speed

ATTENTION:

If a hazard of injury due to movement of equipment or material exists,

an auxiliary mechanical braking device must be used.

ATTENTION:

This feature should not be used with synchronous or permanent

magnet motors. Motors may be demagnetized during braking.