Advanced Display Group (continued)

d334 [Fault 8 Code]

Related Parameter(s):

A197

(With FRN 6.xx and later.)
A code that represents the eighth most recent drive fault. The codes will appear in these parameters
in the order they occur (

d307

[Fault 1 Code] = the most recent fault). Repetitive faults will only be

recorded once. As faults occur, this parameter will be overwritten by [Fault 7 Code].
Refer to

Chapter 4

for fault code descriptions.

Values

Default:

Read Only

Min/Max:

0/122

Display:

1

d335 [Fault 9 Code]

Related Parameter(s):

A197

(With FRN 6.xx and later.)
A code that represents the ninth most recent drive fault. The codes will appear in these parameters in
the order they occur (

d307

[Fault 1 Code] = the most recent fault). Repetitive faults will only be

recorded once. As faults occur, this parameter will be overwritten by [Fault 8 Code].
Refer to

Chapter 4

for fault code descriptions.

Values

Default:

Read Only

Min/Max:

0/122

Display:

1

d336 [Fault 10 Code]

Related Parameter(s):

A197

(With FRN 6.xx and later.)
A code that represents the tenth most recent drive fault. The codes will appear in these parameters in
the order they occur (

d307

[Fault 1 Code] = the most recent fault). Repetitive faults will only be

recorded once. As faults occur, this parameter will be overwritten by [Fault 9 Code].
Refer to

Chapter 4

for fault code descriptions.

Values

Default:

Read Only

Min/Max:

0/122

Display:

1

d337 [Fault 4 Time-hr]

Related Parameter(s):

A195

,

d316

(With FRN 6.xx and later.)
Displays the value of the

d316

[Elapsed Time-hr] parameter when the fault occurred.

Values

Default:

Read Only

Min/Max:

0/32767 Hr

Display:

1 Hr