Programming and Parameters

PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P

Advanced Display Group

d301 [Control Source]

Related Parameter(s):

P036

,

P038

,

T051

-

T054

Displays the active source of the Start Command and Speed Command which are normally defined
by the settings of

P036

[Start Source] and

P038

[Speed Reference] but may be overridden by digital

inputs. Refer to the flowcharts on pages

1-28

and

1-29

for details.

Values

Default:

Read Only

Min/Max:

0/99

Display:

1

Start Command

Digit 0

0 = Keypad
1 = Terminal Block
2 = Communications

Speed Command

Digit 1

0 = Local Keypad Potentiometer
1 =

A142

[Internal Freq]

2 = Analog Input 1
3 = Analog Input 2
4 =

A143

-

A146

[Preset Freq x]

(

T051

-

T053

[Digital Inx Sel] must be set to 4)

5 = Communications

Reserved

Digit 2

Reserved

Digit 3

d302 [Contrl In Status]

Related Parameter(s):

b002

,

P036

,

T051

-

T054

Status of the control terminal block control inputs.
Important: Actual control commands may come from a source other than the control terminal block.

Values

Default:

Read Only

Min/Max:

0/1

Display:

1

1 = Condition True, 0 = Condition False

Start/FWD In

I/O Terminal 02

Dir/REV In

I/O Terminal 03

Stop Input

I/O Terminal 01

Digital In 1

I/O Terminal 05

Digital In 2

I/O Terminal 06

Digital In 3

I/O Terminal 07

Digital In 4

I/O Terminal 08

Not Used