B008, Basic display group, Continued) – Rockwell Automation 22C PowerFlex 400 AC Drive FRN 1.xx - 7.xx User Manual

Page 63

Advertising
background image

Programming and Parameters

3-5

PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual

Publication 22C-UM001I-EN-P

Basic Display Group

(continued)

b006 [Drive Status]

Related Parameter(s):

A166

Present operating condition of the drive.

Values

Default:

Read Only

Min/Max:

0/1

Display:

1

1 = Condition True, 0 = Condition False

Running

Bit 1

Forward

Bit 2

Accelerating

Bit 3

Decelerating

Bit 4

b007 [Fault 1 Code]

Related Parameter(s):

A186

,

A197

,

d307

-

d315

A code that represents a drive fault. [Fault 1 Code] is the most recent fault. Repetitive faults will only
be recorded once.
Refer to

Chapter 4

for fault code descriptions.

Values

Default:

Read Only

Min/Max:

0/122

Display:

1

b008 [Process Display]

Related Parameter(s):

b001

,

A160

32 bit parameter.

The output frequency scaled by

A160

[Process Factor].

Values

Default:

Read Only

Min/Max:

0.00/9999.99

Display:

0.01 – 1

32

Output

Freq

Process

Factor

Process

Display

=

x

b010 [Output Power]

Output power present at T1, T2 & T3 (U, V & W).

Values

Default:

Read Only

Min/Max:

0.0/999.9 kW

Display:

0.1 kW

Advertising