For the Widg-O-Matic example, the parameters are edited as follows:

Widg-O-Matic Parameter File

Parameter File Configuration

Gantry_X_Axis

#1=::[CLX]

#2=::[CLX]Gantry_X_Axis_FP

Gantry_Y_Axis

#1=::[CLX]

#2=::[CLX]Gantry_Y_Axis_FP

Conveyor_Drive #1=::[CLX]Conveyor_Drive_FP

Diverter_Drive

#1=::[CLX]

#2=::[CLX]Diverter_Drive_FP

EquipmentStatus

#1=::[CLX]Gantry_X_Axis_FP

#2=::[CLX]Gantry_Y_Axis_FP

#3=::[CLX]Conveyor_Drive_FP

#4=::[CLX]Diverter_Drive_FP

#5=::[CLX]Diverter_Drive_FP

#6=::[CLX]Diverter_Drive_FP

#7=::[CLX]Diverter_Drive_FP

#8=::[CLX]Diverter_Drive_FP

#9=::[CLX]Diverter_Drive_FP

Startup

#1=::[CLX]

#2=::[CLX]WidgOmatic

StateDiagram #1=::[CLX]WidgOmatic

The Equipment Status faceplate requires that
parameters are set for all rows #1…9 even if they
are not visible. Typically, the last visible row
parameter is entered in the remaining
parameters. For example, Diverter_Drive_FP
parameter entered for #4…9.

Refer to Configure Equipment Status Faceplate
Display on

page 138

for more information.