Rockwell Automation 193 Drives and Motion Accelerator Toolkit Quick Start User Manual

Page 297

Advertising
background image

Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

297

Controller, Network, and Device Configuration Without the DMAT Wizard

Appendix G

This assigns the associated axes to the control module.

17.

Click the Digital Input tab.

The digital inputs (1…4) are assigned default values.

You can reassign them, using the pull-down menus, according to the needs of your application. You can also
unassign digital inputs, if your application does not use them or you want to remove the default
assignments.

For the Widg-O-matic machine example, digital inputs 1 and 2 are assigned Enable and Home
(respectively) and digital inputs 3 and 4 are unassigned.

IMPORTANT

For PowerFlex 755 CIP Motion drives, you must configure the motor feedback device. Refer to your PowerFlex 755 user
manual, publication

750-UM001

, for more information.

IMPORTANT

PowerFlex 755 CIP Motion drives support only one digital input. Refer to your PowerFlex 755 user manual, publication

750-UM001

, for more information.

Widg-O-matic X-Y Gantry Digital Input Assignments

Axis

Axis Name

Digital Input 1

Digital Input 2

1

Gantry_X_Axis

Enable

(1)

(1) When using the Enable digital input, you can add a check in the device module code to make

sure it is on before running your machine. Refer to the steps below to see how.

Home

2

Gantry_Y_Axis

Enable

Home

Advertising