Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

351

Controller, Network, and Device Configuration Without the DMAT Wizard

Appendix G

8.

The Configure Tag References dialog box opens.

9.

Replace Final Tag Names with the associated drive and machine names you have already configured.

a. Replace _DeviceName of _DeviceName:I, _DeviceName:O, _DeviceName:FP, and

_DeviceName_MSG tags with the name of your E3 Plus device.

b. Replace _MachineName of _MachineName tag with the machine name of your project.

c. Replace _ModuleName of _ModuleName tag with the device name of your E3 Plus device.

If a device module with energy support was selected, there will be additional tags named
_DeviceName_BEO.

d. Replace _DeviceName in all of these tags with the name of your E3 Plus device.

10.

Click Other Components within the Import Content organizer.

The Configure Component References dialog box opens.

11.

Replace the Final name (_DeviceName) with the name of your E3 Plus device.

12.

Click OK.

The new Device Module Program appears in the Controller Organizer within the Main
Task folder.

If a device module with energy support was selected, the program will contain an additional
routine named R05_Energy. Refer to Set MSG Path in the E3 Plus Energy Monitoring Routine on

page 81

, for

more information.