Commissioning kinetix 300 drives, Apply power to the drive, Status indicators – Rockwell Automation 193 Drives and Motion Accelerator Toolkit Quick Start User Manual

Page 163: Configure the drive, Test and tune the drive

Advertising
background image

Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

163

System Commissioning

Chapter 6

Commissioning Kinetix 300 Drives

These commissioning procedures apply specifically to the Kinetix 300 drives.

For more information on drive commissioning for Kinetix 300 drives, refer to the appropriate user manual listed
in

Additional Resources

on

page 15

.

Apply Power to the Drive

If using separate 24V DC logic power, apply 24V DC and observe the four-character display. If the four-character
display is ON, apply mains drive power. If not using separate 24V DC logic power, apply mains drive power.

Status Indicators

Verify the drives are ready.

Four-character Display Status Indicators

Configure the Drive

Use MotionView OnBoard software to configure the drive/motor combination and the mode required for your
application.

Test and Tune the Drive

Use MotionView OnBoard software to run the Hookup test and Tune test.

For testing the drive if using an incremental encoder, use MotionView OnBoard software to perform the
Check Phasing test. This test isn’t required if using an absolute encoder.

For tuning the drive, use MotionView OnBoard software to perform Autotuning. The Auto Tune
procedure calculates the gain values dynamically after determining inertia. To perform Auto Tune, the
drive must be in Auto Tune mode.

For more information on test and tune procedures for Kinetix 300 drives, refer to the appropriate user manual
listed in

Additional Resources

on

page 15

.

Status
Indicator

Function

Description

A

Enable

Orange status indicator means that the drive is enabled (running).

B

Regen

Yellow status indicator means the drive is in Regeneration mode.

C

Data entry

Yellow status indicator flashes when changing.

D

Drive fault

Red status indicator illuminates upon a drive fault.

E

Comm activity

Green status indicator flashes to indicate communication activity.

Kinetix 300 Status Indicators