Step 13 – Rockwell Automation 193 Drives and Motion Accelerator Toolkit Quick Start User Manual

Page 306

Advertising
background image

306

Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

Appendix G

Controller, Network, and Device Configuration Without the DMAT Wizard

The New Tag dialog box opens.

9.

Type the axis Name.

AXIS_SERVO_DRIVE is the default Data Type.

10.

Click OK.

The axis appears under the Ungrouped Axes folder
in the Controller Organizer.

11.

Assign your axis to Node 1.

12.

Click Apply.

13.

Click the Power tab.

14.

From the Bus Regulator Configuration pull-down
menu, choose the shunt option appropriate for your
actual hardware configuration.

If your IAM power module is

And your hardware configuration includes this shunt option

Then choose

Configured as an IAM module or
common-bus leader IAM module

(1)

(1) Drive will not accept Internal, <none>, 2094-BSP2, or 1394-SRxxxx selection if DC bus voltage is present without having three-phase power applied.

Internal shunt resistors only

Internal or <none>

Bulletin 2094 (rail mounted) shunt module

(2)

(2) To use the 2094-BSP2 shunt module with 2094-BCxx-Mxx-M power modules, you must be using Motion Database 5.12.1 or later. Contact Rockwell Automation Technical Support for more

information.

2094-BSP2

Bulletin 1394 passive shunt module (connected to the 2094-BSP2 shunt
module)

1394-SRxxxx

Bulletin 1336 active shunt module

Internal or <none>

Configured as a common-bus follower IAM module

(3)

(3) Drive will not accept CommonBus Follow selection if three-phase power or DC bus power is applied.

N/A. Shunts are disabled on follower IAM module

CommonBus Follow