Configure the ethernet module – Rockwell Automation 193 Drives and Motion Accelerator Toolkit Quick Start User Manual

Page 273

Advertising
background image

Rockwell Automation Publication IASIMP-QS019E-EN-P - August 2013

273

Controller, Network, and Device Configuration Without the DMAT Wizard

Appendix G

Configure the Ethernet Module

Follow these steps to configure Ethernet communication for your HMI terminal, PowerFlex drive, Kinetix 300,
Kinetix 5500, and Kinetix 6500 servo drives.

1.

Expand I/O Configuration in the Controller
Organizer.

2.

Right-click I/O Configuration and choose New
Module.

The Select Module dialog box opens.

3.

Expand the Communications category and select
your 1756 Ethernet module.

For systems using Integrated Motion on the
EtherNet/IP network, 1756-EN2

x or 1756-EN3x

module are required.

In this example, the 1756-EN2TR module is
selected.

4.

Click OK.

The New Module dialog box opens.

5.

Configure the new module.

a. Type the module Name.

b. Enter the Logix5000 EtherNet/IP

module slot (leftmost slot = 0).

c. Select an Ethernet Address option.

In this example, the Private
Network address is selected.

d. Enter the address of your

EtherNet/IP module.

In this example, the last octet of the address is 10.

6.

Click Change in the Module Definition area.

Advertising