Motion Drives Faceplates

The Motion drives faceplates are typically launched from the Machine Startup or Equipment Status faceplate’s
corresponding Goto display buttons.

Home View

Faceplate Toolbar Buttons

TIP

The Kinetix 300, sercos interface, and CIP Motion faceplates are similar in layout and the information they show, although
differences do exist. The examples shown in this section are for CIP Motion drives.

Function
Button

Icons

Description

Function
Button

Icons

Description

Alarm

The Alarm button indicates a drive fault condition
and activates fault diagnostic views. A grey bell
indicates normal status, with no faults. A yellow
flashing bell indicates a fault condition.

Axis Control

From the Axis Control display you can home,
enable, disable, reset an axis fault, and manually
control the drive.

Configuration

The Configuration button lets you edit the faceplate
name or name of the device.

Help

The Help button provides information for the
existing view.

Trending

The Trending button shows you position, velocity,
and current/torque trends.

Close

Click the Close button to close the faceplate.

Axis Status

From the Axis Status display you can view general
motion, axis, and drive status.

Faceplate

Toolbar

Status

Indicators

Close
Button

Title Bar

CIP Motion Drive