SDM-300A Satellite Modem

Revision 6

Front Panel Operation

MN/SDM300A.IOM

5–29

FUNCTION SELECT: CONFIGURATION: INTERFACE:LOOP TIMING

LOOP TIMING

OFF

Loop Timing: On or Off


Programs the transmit clocking to the RX satellite clock.

TX and RX data rates must be equal unless the asymmetrical loop timing option is enabled.

FUNCTION SELECT: CONFIGURATION: INTERFACE:TX DATA FAULT
(CONDITIONAL)

TX DATA FAULT

NONE

IMPORTANT

Conditional: This command is only available when the overhead
interface PCB is installed.

This is a test mode.


TtRANSMIT DATA FAULT. Press [

↑] or [↓] to make the selection. Press [ENTER] to execute

the change.

NONE

The transmit interface fault Data/AIS is not activated.

ALARM INDICATION SIGNAL
(AIS)

Sets transmit interface fault Data/AIS to monitor a fault
condition of all 1s from customer data input to the modem.

DATA

Sets transmit interface fault Data/AIS to monitor a fault
condition of all 1s or 0s. This is referred to as a data-stable
condition, which means that the data is not transitioning.