Comtech EF Data SDM-300A User Manual

Page 432

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Remote Control Operation

MN/SLM3650.IOM

A–40

Common
Equipment
Status

Command:
Response:

<add/CES_'cr'
>add/CES_'cr'
M&C_xxx'cr'
INT_xxx'cr'
BAT_xxx'cr'
+5_xxx'cr'
+12_xxx'cr'
-12_xxx'cr'
ST_xxx'cr'
MODE_xxxxxx'cr'
SFLT_xx'cr''lf']



Monitor & Control Module (OK/FLT)
Data Interface/Overhead Module (OK/FLT)
Battery/Clock (OK/FLT)
+5V Power Supply (OK/FLT)
+12V Power Supply (OK/FLT)
-12V Power Supply (OK/FLT)
Self Test (OK/FLT)
Mode (LOCAL or REMOTE)
Number of stored faults logged (0 to 10)

The common equipment status command causes a block of data
to be returned which indicates the status of the common
equipment.

Interface
Alarms
(Backward
Alarm)
Status

Command:
Response:

<add/IAS_'cr'
>add/IAS_'cr'
TXBWA1_xxx'cr'
TXBWA2_xxx'cr'
TXBWA3_xxx'cr'
TXBWA4_xxx'cr'
RXBWA1_xxx'cr'
RXBWA2_xxx'cr'
RXBWA3_xxx'cr'
RXBWA4_xxx'cr'
SFLT_xx'cr''lf']



TX Backward Alarm 1 (FLT/OK)
TX Backward Alarm 2 (FLT/OK)
TX Backward Alarm 3 (FLT/OK)
TX Backward Alarm 4 (FLT/OK)
RX Backward Alarm 1 (FLT/OK)
RX Backward Alarm 2 (FLT/OK)
RX Backward Alarm 3 (FLT/OK)
RX Backward Alarm 4 (FLT/OK)
Number of stored faults logged (0 to 10)