FUNCTION SELECT: FAULTS/ALARMS: MODULATOR

MODULATOR

---------


IF SYNTHESIZER

Modulator IF synthesizer fault.

DATA CLOCK SYN

Transmit clock synthesizer fault. Indicates the internal Voltage Controlled
Oscillator (VCO) has not locked to the incoming data clock.

I CHANNEL

I channel data activity fault.

Q CHANNEL

Q channel data activity fault.

AGC LEVEL

TX IF AGC level fault.

MODEM REF ACT

MODEM REF activity alarm.

MODEM REF PLL

MODEM REF PLL not locked.

MODULE

Modulator module fault.

CONFIGURATION

Modulator configuration fault.

FUNCTION SELECT: FAULTS/ALARMS: DEMODULATOR


DEMODULATOR

+------

CARRIER DETECT

Carrier detect fault. Indicates the decoder is not locked.

IF SYNTHESIZER

Demodulator IF synthesizer fault. Indicates the IF synthesizer is not locked.

I CHANNEL

I channel activity fault. Indicates a loss of activity in the I channel of the
quadrature demodulator.

Q CHANNEL

Q channel activity fault. Indicates a loss of activity in the Q channel of the
quadrature demodulator.

BER THRESHOLD

Secondary alarm result of the BER threshold set in the DEMOD
Configuration menu.

MODULE

Demodulator/decoder module fault.

CONFIGURATION

Demodulator/decoder configuration fault.