ASYNC/AUPC Interface

MN/SDM300A.IOM

11–6

11.2.1.1 Remote

AUPC

This feature allows the user to monitor and control a remote modem location using the
front panel or serial port of the local modem. The operator can set or reset the following
commands:

• Baseband loopback
• TX 2047 pattern
• AUPC enable

11.2.1.1.1 Remote

Modem

AUPC Configuration and Monitor

The menu for this feature is remote AUPC, which is at the same level as the
Configuration and Monitor menus. The menus are structured as follows:

Menu

Description

Function Select Remote AUPC

Press <ENTER> to proceed.

Remote AUPC Configuration

Press <ENTER> to proceed.

AUPC Enable

Select On to enable Remote AUPC.

B-Band LoopBack

Select On to place the unit at the distant end of the link in
loopback.

TX 2047 Pattern

Select On for the distant end to TX a 2047 pattern. Select Off to
stop the pattern distant end.

Remote AUPC Monitor

Press <ENTER> to proceed.

2047 Error

This indicates the BER at the distant end measured from the 2047
pattern. This requires that the 2047 pattern is tuned On at the near
end.

11.2.2

Self-Monitoring Local Modem AUPC Control

This AUPC mode allows the modem to adjust its carrier power to maintain a target
Eb/No while it monitors its own carrier returned through the satellite. This is often used
in broadcast applications where a hub maintains control of the outbound carrier that is
delivered to many remotes. This requires that the Earth Station is located within the
satellite footprint.

The self-monitoring AUPC does not require any special hardware or software options.
However, if the Overhead Card or Reed-Solomon Cards are installed, do not select either
the ASYNC or AUPC from the Modem Type menu located under the Utility: Modem
Type
menu, because these are used for AUPC between two modems.

To setup the modem for the self-monitoring operation, enter the Local Modem AUPC
menu located under the Utilit: Modem Type menu and select On. This enables the
Configuration: Local AUPC menu to permit adjustment of the AUPC parameters
described in Table 11-1.