A–38

the current configuration of the interface. Additional configuration
status of new options and features will always be appended to
the end.

Notes:

1. Data is only returned for TX D&I Overhead.
2. Data is only returned for RX D&I Overhead.
3. Data is only returned for TX IDR Overhead.
4. Data is only returned for RX IDR Overhead.
5. Data is only returned for TX ASYNC Overhead.
6. Data is only returned for RX ASYNC Overhead.
7. Data is only returned if MUX PCB (Card Slot #1) is installed.
8. Data is only returned if FLEX MUX PCB (Card Slot #1) is installed.
9. Data not returned if TX Channel #1 is disabled (with Flex Mux PCB installed).
10. Data not returned if TX Channel #3 is disabled or set for AUPC (with Flex Mux PCB installed).
11. Data not returned if TX Channel #4 is disabled or set for AUPC (with Flex Mux PCB installed).
12. Data not returned if RX Channel #1 is disabled (with Flex Mux PCB installed).
13. Data not returned if RX Channel #3 is disabled or set for AUPC(with Flex Mux PCB installed).
14. Data not returned if RX Channel #4 is disabled or set for AUPC

(with Flex Mux PCB installed).

A.15

Modem Fault Status

Modem Faults
Status
(Summary)

Command:
Response:

<add/MFS_'cr'
>add/MFS_'cr'
DMD_xxx'cr'
MOD_xxx'cr'
TX_xxx'cr'
IRX_xxx'cr'
CEQ_xxx'cr'
BWAL_xxx'cr'’lf']



Demodulator (FLT/OK)
Modulator (FLT/OK)
Interface Transmit Side (FLT/OK)
Interface Receive Side (FLT/OK)
Common Equipment (FLT/OK)
Backward Alarms (FLT/OK)

Modulator
Status

Command:
Response:

<add/MS_'cr'
>add/MS_'cr'
RF_xxx'cr'
MOD_xxx'cr'
SYN_xxx'cr'
DCS_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
AGC_xxx'cr'
SCT_xxx'cr'
EXT_xxx'cr'
CONF_xxx'cr'
SFLT_xx'cr''lf']



RF Output (ON/OFF) actual status not config
Module (OK/FLT)
IF Synthesizer (OK/FLT)
Data Clock Synthesizer (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
AGC Level (OK/FLT)
Modem Reference PLL Lock (OK/FLT)
Modem Reference Activity (OK/FLT)
Configuration (OK/FLT)
Number of stored faults logged (0 to 10)