SDM-300A Satellite Modem

Revision 6

ASYNC/AUPC Interface

MN/SDM300A.IOM

11–14

11.4.3.1

Configuration #1 (Local EIA-232 to Remote EIA-232)

Table 11-3. Local EIA-232 to Remote EIA-232

#1. Local End Modem Settings for EIA-232

Utility Interface Menu

ASYNC TX and RX Type

EIA-232

Configuration Interface Menu

ASYNC TX and RX Baud Rate

150 to 38400

(See 11.4.1)

ASYNC TX and RX Length

7 bits

ASYNC TX and RX Parity

Even

ASYNC TX Stop

2 bits

#1. Remote End Modem Settings for EIA-232

Utility Interface Menu

ASYNC TX and RX Type

EIA-232

Configuration Interface Menu

ASYNC TX and RX Baud Rate

150 to 38400

(See 11.4.1)

ASYNC TX and RX Length

7 bits

ASYNC TX and RX Parity

Even

ASYNC TX Stop

2 bits

Utility System Menu

Remote Baud Rate

Equal to ASYNC TX and RX baud rate

Parity Even
Address

1 to 255


The local end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the EIA-232 remote terminal (WYSE or laptop
computer). The pinout of the local cable is listed in the following table.

#1. Local End EIA-232

9-Pin

Female Connector

25-Pin

Male Connector

RX 2 3 TX

TX 3 2 RX

GND 5 7 GND

The remote end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the 9-pin female connector, J6, at the rear of the
modem. The pinout of the remote cable is listed in the following table.

#1. Remote End EIA-232

9-Pin

Male Connector

25-Pin

Male Connector

RX 2 2 RX

TX 3 3 TX

GND 5 7 GND