FUNCTION SELECT: UTILITY: SYSTEM: DISPLAY CONTRAST

DISPLAY CONTRAST

LEVEL:

64

Range: 0 to 100


Sets the contrast setting of the Front Panel menu.

Press [ENTER] to begin. Press [

↑] or [↓] to increase or decrease the number at the flashing

cursor, from 0 to 100. Press [ENTER] to execute the change

FUNCTION SELECT: UTILITY: SYSTEM: EXT AGC: MIN PWR

EXT AGC: MIN PWR

0.0 Volts

Range: 0.0 to 10.0, in 0.5V steps


Sets the AGC voltage for a RX signal level of -25.0 dBm. Upon entry, the current external AGC
voltage level is displayed. Press [

↑] or [↓] to increase or decrease the AGC voltage level in

0.5V steps. Press [ENTER] to execute the change.

Note: For any receive signal level between -25.0 and -60.0 dBm, the software will interpolate
the required AGC voltage.

FUNCTION SELECT: UTILITY: SYSTEM: EXT AGC: MAX PWR

EXT AGC: MAX PWR

10.0 Volts

Range: 0.0 to 10.0, in 0.5V steps


Sets the AGC voltage for a RX signal level of -60.0 dBm. Upon entry, the current external AGC
voltage level is displayed. Press [

↑] or [↓] to increase or decrease the AGC voltage level in

0.5V steps. Press [ENTER] to execute the change.

Note: For any receive signal level between -25.0 and -60.0 dBm, the software will interpolate
the required AGC voltage.