Functional Description

MN/SDM300A.IOM

2–16

A backward alarm being received on a particular link is detected by one of the two following
methods:

• The backward alarm output drives a FORM C relay with all three contacts available on

the data connector.


• The status of all transmit and receive backward alarms may be read through the RS-232

or RS-485 remote interface connector that is integrating a modem or switch into a
computer network.


In addition to the four backward alarms for IDR and two backward alarms (primary and
secondary) for IBS, all modes support the following faults:

• MOD (modulator equipment)
• DEM (demodulator equipment)
• CEQ (common equipment)


Each fault is indicated by a FORM C relay contact and an open collector output.