System specifications, Loopback modes, Test modes – Comtech EF Data SDM-300A User Manual

Page 388: 2 test modes

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Specifications

MN/SDM300A.IOM

19–32

19.10 System

Specifications

19.10.1 Loopback

Modes

The operator can select one of the following interface loopback test modes.

• Baseband: Near end and far end.
• Interface: Near end and far end (Reed-Solomon or Overhead only).

19.10.2 Test

Modes

Note: The TX and RX data rates must be the same for the modem to lock.

Table 19-21. Test Modes

IF Loopback:

Disconnects the IF input from the RX input connector and couples it to a sample of

the TX IF output. The IF output is not affected.

RF Loopback

Sets the demodulator frequency to the same value as the modulator. For the

modem to lock, an external IF loop must be provided.

BIST (Built in Self Test)

The modem has the ability to generate 2

11-1

(2047) PN data and pass the data

through the Interface, Modulator and Demodulator sections of the modem. The

modem can generate noise in the IF path to simulate a satellite environment. The
true BER can then be measured by the modems built in BER monitor. This feature

can be invoked on power up or by the operator and the result checked against

specification and a fault is flagged if the unit fails. The feature can be turned off at

the front panel if so desired to minimize initialization time. The RF output is off

during this self test

2047 Pattern Generator (must
have overhead card installed

and activated)

Inserts an Industry Standard 2047 pattern in lieu of the TX data stream.

2047 Pattern Monitor (must
have overhead card installed

and activated)

Monitors the RX data for 2047 pattern. If 2047 pattern is present, this test mode

provides an indication of Bit Error Rate (BER). The RX data is not interrupted.

Advertising