Fault connector and pinouts (j7), 2 fault connector and pinouts (j7) – Comtech EF Data SDM-300A User Manual

Page 83

Advertising
background image

SDM-300A Satellite Modem

Revision 6

External Connections

MN/SDM300A.IOM

4–5

4.1.2

Fault Connector and Pinouts (J7)

The fault connector provides Form C contact closures for fault reporting. The three Form C
summary fault contacts, ratings 1A maximum at 24 VDC, 0.5A at 120 VAC, are Modulator,
Demodulator, and Common Equipment.

The fault interface connection is a 9-pin subminiature female D connector (J7) located on the rear
panel of the modem. Screw locks are provided for mechanical security on the mating connector.
Refer to Table 4-3 for pinout information.

Table 4-3. Fault Connector and Pinouts (J7)

Pin #

Signal Function

Name

1

Common equipment is not faulted

NO

2

COM

3

Common equipment is faulted

NC

4

Modulator is not faulted

NO

5

COM

6

Modulator is faulted

NC

7

Demodulator is not faulted

NO

8

COM

9

Demodulator is faulted

NC

Note: A connection between the common (COM) and normally open (NO) contacts
indicates no fault.

To obtain a system summary fault, connect all the Form C contacts in parallel.