A–59

(Note 14)


(Note 14)


(Note 17)

139


140


141


RX Flex Mux Channel #4 Clock Phase
(ref. "RCCP_4" command).

RX Flex Mux Channel #4 Data Phase
(ref. "RCDP_4" command).

G.703 Operation
(ref. “G7LT_”command)


p139 = n, where 'n' is '0' (Normal) or '1' (Invert).


p140 = n, where 'n' is '0' (Normal) or '1' (Invert).


P141 = n, where ‘n’ is ‘0’ for UNBAL or ‘1’ for BAL.


Notes:

1. Data will only be returned if TX Overhead is programmed for D&I (or TX Flex MUX D&I). Comma is always returned.
2. Data will only be returned if RX Overhead is programmed for D&I (or RX Flex MUX D&I). Comma is always returned.
3. Data will only be returned if TX Overhead is programmed for ASYNC. Comma is always returned.
4. Data will only be returned if RX Overhead is programmed for ASYNC. Comma is always returned.
5. Data will only be returned if TX Overhead is programmed for IDR. Comma is always returned.
6. Data will only be returned if RX Overhead is programmed for IDR. Comma is always returned.
7. Not

Used.

8. Data is only returned if Flex MUX PCB (Card Slot #1) is installed.. Comma is always returned.
9. Data not returned if TX Channel #1 is disabled. Comma is always returned.
10. Data not returned if TX Channel #3 is disabled or set for AUPC. Comma is always returned.
11. Data not returned if TX Channel #4 is disabled or set for AUPC. Comma is always returned.
12. Data not returned if RX Channel #1 is disabled. Comma is always returned.
13. Data not returned if RX Channel #3 is disabled or set for AUPC. Comma is always returned.
14. Data not returned if RX Channel #4 is disabled or set for AUPC. Comma is always returned (except for last parameter).
15. Data will only be returned if TX Overhead is programmed for ASYNC/AUPC. (or TX Flex Mux AUPC). Comma is always

returned.

16. Data will only be returned if RX Overhead is programmed for ASYNC/AUPC. (or RX Flex Mux AUPC). Comma is always

returned.

17. Data will only be returned if G.703 Personality PCB is installed. Comma is always returned.

Advertising