Comtech EF Data SDM-300A User Manual

Page 297

Advertising
background image

SDM-300A Satellite Modem

Revision 6

ASYNC/AUPC Interface

MN/SDM300A.IOM

11–15

11.4.3.2

Configuration #2 (Local EIA-232 to Remote EIA-485 [4-Wire])

Table 11-4. Local EIA-232 to Remote EIA-485 (4-Wire)

#2. Local End Modem Settings for EIA-232 (4-Wire)

Utility Interface Menu

ASYNC TX and RX Type

EIA-232

Configuration Interface Menu

ASYNC TX and RX Baud Rate

150 to 38400

(See 11.4.1)

ASYNC TX and RX Length

7 bits

ASYNC TX and RX Parity

Even

ASYNC TX Stop

2 bits

#2. Remote End Modem Settings for EIA-485 (4-Wire)

Utility Interface Menu

ASYNC TX and RX Type

EIA-485 (4-wire)

Configuration Interface Menu

ASYNC TX and RX Baud Rate

150 to 38400

(See 11.4.1)

ASYNC TX and RX Length

7 bits

ASYNC TX and RX Parity

Even

ASYNC TX Stop

2 bits

Utility System Menu

Remote Baud Rate

Equal to ASYNC TX and RX baud rate

Parity Even
Address 1

to

255


The local end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the EIA-232 (4-wire) remote terminal (WYSE or laptop
computer). The pinout of the local cable is listed in the following table.

#2. Local End EIA-232

9-Pin

Female Connector

25-Pin

Male Connector

RX 2 3 TX

TX 3 2 RX

GND 5 7 GND


The remote end cable connects the 25-pin female ASYNC connector (on either the
breakout panel or the Y cable) to the 9-pin female connector, J6, at the rear of the
modem. The pinout of the remote cable is listed in the following table.

#2. Remote End EIA-485 (4-Wire)

Twisted Pair

9-Pin

Male Connector

25-Pin

Male Connector

TX+ 4 16 RX+

TX- 5 3 RX-

RX+ 8 14 TX+

RX- 9 2 TX-