Function select monitor:corrected ber, Function select monitor:eb/no – Comtech EF Data SDM-300A User Manual
Page 151
SDM-300A Satellite Modem
Revision 6
Front Panel Operation
MN/SDM300A.IOM
5–57
FUNCTION SELECT MONITOR:CORRECTED BER
CORRECTED BER
4.0 E-3
Corrected BER Range: 1.0 E-3 to 1.0 E-12, or No Data
Displays the current corrected BER or “No Data” (if carrier is not locked).
Notes:
1. Low limit is based on performance.
2. High limit is 1.0 E-12.
Press[
←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected
kbps. Press [ENTER] to execute the change.
FUNCTION SELECT MONITOR:EB/NO
EB/NO
16.0 dB
Eb/No Range: 2.0 to 16.0 dB, or No Data
Displays the current E
b
/N
0
or “No Data” (if carrier is not locked).
Notes:
1. Low limit is based on the data rate.
2. High limit is 16.0 dB.
Press[
←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected
kbps. Press [ENTER] to execute the change.