Table 8-1. Minimum Doppler/Plesiochronous Buffer Capacity Requirements

Satellite Orbit Inclination

Buffer Capacity (ms)

For Various Circuit Configuration

(Degrees)

Master/Master

Master/Slave

0.1 (Nomnal)

1.5

2.4

0.5 2.5

4.4

1.0 3.9

7.4

1.5 5.5

10.4

2.0 6.9

13.2

2.5 8.5

16.4

3.0 9.9

19.2

4.0 12.9

25.2

Notes:

1. The above minimum buffer capacities include a factor of two to allow the buffer to start in the

center and then drift in either direction. In the Master/Slave case, where the TX timing at one end
of the link is derived from the demodulator and used to TX back to either the station which

originated the timing signal or to a different station, another factor of two has been applied to the

Doppler contribution to account for the passage of the timing signal twice through the satellite.

2. Adding the buffer requirements due to satellite delay variations (Doppler) and that due to the

interfacing of different national clocks (plesiochronous) derived the above capacities.

3. Actual buffer capacity is likely to be larger due to the need to slip primary order streams on a

multiframe basis.