Function select monitor:receive signal, Function select monitor:sweep frequency, Function select monitor:buffer fill – Comtech EF Data SDM-300A User Manual

Page 152

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Front Panel Operation

MN/SDM300A.IOM

5–58

FUNCTION SELECT MONITOR:RECEIVE SIGNAL

RECEIVE SIGNAL

-45.0dBm

Receive Signal Range: -25.0 to -60.0 dBm


Displays the current receive signal level.

Press[

←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected

kbps. Press [ENTER] to execute the change.

FUNCTION SELECT MONITOR:SWEEP FREQUENCY

SWEEP FREQUENCY

+ 0 Hz

Sweep Frequency Range: -35,000 to +35,000 Hz, or No Data


Displays the current offset frequency or “No Data” (if carrier is not locked).

Press[

←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected

kbps. Press [ENTER] to execute the change.

FUNCTION SELECT MONITOR:BUFFER FILL

BUFFER FILL

50%

Buffer Fill Status: 1 to 99%.


Displays the current plesiochronous buffer fill status (percent).