SDM-300A Satellite Modem
Revision 6
Front Panel Operation
MN/SDM300A.IOM
5–58
FUNCTION SELECT MONITOR:RECEIVE SIGNAL
RECEIVE SIGNAL
-45.0dBm
Receive Signal Range: -25.0 to -60.0 dBm
Displays the current receive signal level.
Press[
←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected
kbps. Press [ENTER] to execute the change.
FUNCTION SELECT MONITOR:SWEEP FREQUENCY
SWEEP FREQUENCY
+ 0 Hz
Sweep Frequency Range: -35,000 to +35,000 Hz, or No Data
Displays the current offset frequency or “No Data” (if carrier is not locked).
Press[
←] or [→] to move the flashing cursor, and [↑] or [↓] to increase or decrease the selected
kbps. Press [ENTER] to execute the change.
FUNCTION SELECT MONITOR:BUFFER FILL
BUFFER FILL
50%
Buffer Fill Status: 1 to 99%.
Displays the current plesiochronous buffer fill status (percent).