Clocking options, Eia-232, eia-422, or v.35 master/master, Eia-232, eia-422, or v.35 master/slave – Comtech EF Data SDM-300A User Manual

Page 221: Chapter 7. clocking options

Advertising
background image

7-1

Chapter 7. Clocking Options

7.1 Clocking

Options

Clocking of the data from the terrestrial equipment to the satellite (and vice
versa) will depend on the application.

7.1.1 EIA-232,

EIA-422,

or V.35 Master/Master

Refer to Figure 7-1 for:

• Clocking block diagram
• Transmit clock options
• Buffer clock options
• V.35 timing signals
• EIA-422 timing signals

7.1.2 EIA-232,

EIA-422,

or V.35 Master/Slave

Refer to Figure 7-2 for:

• Clocking block diagram
• Transmit clock options
• Buffer clock options
• V.35 timing signals
• EIA-422 timing signals

The use of loop timing in the modem is an option for both EIA-422 and V.35
operation.

SCT (LOOP):

SCT (INTERNAL) clock no longer applies when the modem has loop timing on


The TX clock source is now recovered from the RX satellite data. This recovered
clock is put out on the ST line and is used to clock the terrestrial equipment. The
TX terrestrial clock is now essentially the same as the RX satellite clock, except
that it has been buffered by the terrestrial equipment.




Advertising