Transmit if output switch, Transmit if power, Modulator power offset – Comtech EF Data SDM-300A User Manual

Page 366: Modulated if output shape, Spurious emissions, Modulator phase error

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Specifications

MN/SDM300A.IOM

19–10

19.4.11

Transmit IF Output Switch

When set to Off, no signal present at the output is greater than –60 dBm, measured in a
3 kHz bandwidth from 0 to 500 MHz.

19.4.12

Transmit IF Power

The TX IF power is operator selectable from –5 to –30 dBm, in 0.1 dB steps, with an
accuracy of

± 0.5 dB. The maximum drift due to temperature change over the specified

range is

± 0.5 dB.


As an option the output can be selectable from +5 to –20 dBm, in 0.1 dB steps, with an
accuracy of

± 0.5 dB. The maximum drift due to temperature change over the specified

range is

± 0.5 dB.

19.4.13 Modulator

Power

Offset

An offset to the displayed IF output power may be entered from –99.0 to +99.0 dB, in 0.1 dB
steps.

19.4.14

Modulated IF Output Shape

The modem meets the following transmit output spectral mask specifications. The desired
mask is selectable from the front panel or remotely.

• INTELSAT/EUTELSAT
• Closed net (Comtech EF Data and Comstream)
• Closed net (Fairchild compatible)

• Closed net (SDM-51, SDM-52)

19.4.15 Spurious

Emissions

Spurious emissions are measured relative to the power of the modulated carrier. The
measurement is done with the carrier on in continuous mode and modulated by the correct
data/clock signal. Spurious emissions measured in a 3 kHz bandwidth at the transmit IF
output are:

0 to 500 MHz (-5 to –30 dBm)

-55 dBc

0 to 500 MHz (+5 to –20 dBm > 64 kbps)

-50 dBc

0 to 500 MHz (+5 to –20 dBm < 64 kbps)

-45 dBc

19.4.16

Modulator Phase Error

The modulator has less than 2

° of phase error

Advertising