A–39

Demodulator
Status

Command:
Response:

<add/DS_'cr'
>add/DS_'cr'
MOD_xxx'cr'
CD_xxx'cr'
SYN_xxx'cr'
ICH_xxx'cr'
QCH_xxx'cr'
BERT_xxx'cr'
CONF_xxx'cr'
SFLT_xx'cr''lf']



Demod Module (OK/FLT)
Carrier Detect (OK/FLT)
IF Synthesizer Lock (OK/FLT)
I Channel (OK/FLT)
Q Channel (OK/FLT)
BER Threshold (OK/FLT)
Configuration (OK/FLT)
Number of stored faults logged (0 to 10)

Interface
Transmit Side
Status

Command:
Response:

<add/ITXS_'cr'
>add/ITXS_'cr'
DRP_xxx'cr'
TXD_xxx'cr'
PLL_xxx'cr'
CLK_xxx'cr'
TAC1_xxx'cr'
TAC2_xxx'cr'
CONF_xxx'cr'
SFLT_xx'cr''lf']



D&I Drop (OK/FLT)
Transmit Data/AIS (OK/FLT)
Transmit Synthesizer PLL Lock (OK/FLT)
Selected Transmit Clock Activity (OK/FLT)
Transmit Audio Clip Channel #1 (OK/FLT)
Transmit Audio Clip Channel #2 (OK/FLT)
Configuration (OK/FLT)
Number of Stored Faults Logged (0 to 10)

Interface
Receive Side
Status

Command:
Response:

<add/IRXS_'cr'
>add/IRXS_'cr'
UNFL_xxx'cr'
OVFL_xxx'cr'
RXD_xxx'cr'
FBER_xxx'cr'
BWA_xxx'cr'
CLK_xxx'cr'
PLL_xxx'cr'
DMUX_xxx'cr'
2047_xxx'cr'
BUFF_xxx'cr'
INS_xxx'cr'
RAC1_xxx'cr'
RAC2_xxx'cr'
CONF_xxx'cr'
SFLT_xx'cr''lf']



Buffer Underflow (OK/FLT)
Buffer Overflow (OK/FLT)
Receive Data Loss/AIS (OK/FLT)
Frame BER (OK/FLT)
Receive Backward Alarm (OK/FLT)
Selected Buffer Clock Activity (OK/FLT)
Buffer Clock PLL Lock (OK/FLT)
Demux Lock (OK/FLT)
2047 Pattern Lock Detect (OK/FLT)
Buffer Full (OK/FLT)
D&I Insert (OK/FLT)
Receive Audio Clip Channel #1 (OK/FLT)
Receive Audio Clip Channel #2 (OK/FLT)
Configuration (OK/FLT)
Number of Stored Faults Logged (0 to 10)