A.10 – Comtech EF Data SDM-300A User Manual

Page 416

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Remote Control Operation

MN/SLM3650.IOM

A–24

Remote
Interface
Read Error
Status

Command:
Response:

Example:
Command:
Response:

<add/RRES_'cr'
>add/RRES_nE-e'cr''lf']


<add/RRES_'cr'
>add/RRES_2E-6'cr''lf']

Where:
n = 1 to 9 (error rate number).
e = 2 to 6 (exponent).

Note: Received 2047 Pattern.

This command returns 2047 BER from the remote AUPC
modem. If data is not valid, the message 'No_Data' is
returned in lieu of BER data.

A.10

MUX PCB Configuration Commands (MUX PCB Installed Only)

Mux
Tributary
Data Rate &
Enable

Command:
Response:

Status:
Response:

<add/MTDR_x_yyyyyy'cr'
>add/MTDR_x_yyyyyy'cr''lf']

<add/MTDR_x'cr'
>add/MTDR_x_yyyyyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyyyyy = OFF (disabled), or 0.6 to 4000.0 (kbps in 100 bits
steps).

Mux
Tributary
Interface
Type

Command:
Response:

Status:
Response:

<add/MTIT_x_yyyyy'cr'
>add/MTIT_x_yyyyy'cr''lf']

<add/MTIT_x'cr'
>add/MTIT_x_yyyyy'cr''lf']

Where:
x = 1 to 8 (tributary number).
yyyyy = RS422 or RS232.

Mux
Tributary
Clock Phase

Command:
Response:

Status:
Response:

<add/MTCP_x_yyy'cr'
>add/MTCP_x_yyy'cr''lf']

<add/MTCP_x'cr'
>add/MTCP_x_yyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyy = NRM (normal clock phasing), INV (inverted clock
phasing).

Mux
Tributary
Data Phase

Command:
Response:

Status:
Response:

<add/MTDP_x_yyy'cr'
>add/MTDP_x_yyy'cr''lf']

<add/MTDP_x'cr'
>add/MTDP_x_yyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyy = NRM (normal data phasing), INV (inverted data
phasing).

Mux
Tributary
Mode

Command:
Response:

Status:
Response:

<add/MTMD_x_yyyyy'cr'
>add/MTMD_x_yyyyy'cr''lf']

<add/MTMD_x'cr'
>add/MTMD_x_yyyyy'cr''lf']

Where:
x = 1 to 8 (tributary number).
yyyyy = SYNC or ASYNC.