Remote baud rate, Remote address – Comtech EF Data SDM-300A User Manual

Page 44

Advertising
background image

SDM-300A Satellite Modem

Revision 6

Functional Description

MN/SDM300A.IOM

2–4

2.1.2

Remote Baud Rate

The remote communications baud rate and parity are programmed by the front panel control in
the Utility: System menu (refer to Chapter 5). The programmed baud rate and parity are
maintained indefinitely in RAM on the M&C module. The parity bps can be set to EVEN or
ODD. The available baud rate are listed below:

• 110
• 150
• 300
• 600
• 1200
• 2400
• 4800
• 9600
• 19200

2.1.3 Remote

Address

To communicate with the established remote communications protocol, configure each modem
for one address between 1 and 255. Each modem on a common remote communications link
(RS-485) must have a distinct address. Use the front panel control in the Utility: System menu
(Chapter 5) to program the address.

An RS-485/RS-232 communications link remotely controls and monitors all modem functions.
Use the 2- or 4-wire, half-duplex RS-485 interface to connect between two or more modems
and switches on a common communications link. Use the RS-232 interface to communicate
with a single modem.

Note: Address 0 is reserved as a global address which simultaneously addresses all devices on a
given communications link.