Comtech EF Data SDM-300A User Manual
Page 406
![background image](/files/778893/content/doc406.png)
SDM-300A Satellite Modem
Revision 6
Remote Control Operation
MN/SLM3650.IOM
A–14
Interface Read
Error Select
Command:
Response:
Status:
Response:
<add/IRE_xxxxxx'cr'
>add/IRE_xxxxxx'cr''lf']
<add/IRE_'cr'
>add/IRE_xxxxxx'cr''lf']
Where: xxxxxx = ON or OFF.
Note: Receive 2047 Pattern.
Interface Coding
Format Transmit
Command:
Response:
Status:
Response:
<add/ICFT_xxxx'cr'
>add/ICFT_xxxx'cr''lf']
<add/ICFT_'cr'
>add/ICFT_xxxx'cr''lf']
Where: xxxx = AMI, HDB3, or B8ZS.
Interface Coding
Format Receive
Command:
Response:
Status:
Response:
<add/ICFR_xxxx'cr'
>add/ICFR_xxxx'cr''lf']
<add/ICFR_'cr'
>add/ICFR_xxxx'cr''lf']
Where: xxxx = AMI, HDB3, or B8ZS.
Transmit Data
Fault
Command:
Response:
Status:
Response:
<add/TDF_xxxx'cr'
>add/TDF_xxxx'cr''lf']
<add/TDF_'cr'
>add/TDF_xxxx'cr''lf']
Where: xxxx = NONE, DATA, or AIS.
Receive Data
Fault
Command:
Response:
Status:
Response:
<add/RDF_xxxx'cr'
>add/RDF_xxxx'cr''lf']
<add/RDF_'cr'
>add/RDF_xxxx'cr''lf']
Where: xxxx = NONE, DATA, or AIS.
Interface Service
Channel Level
Command:
Response:
Status:
Response:
<add/ISCL_xxx_snn'cr'
>add/ISCL_xxx_snn'cr''lf']
<add/ISCL_xxx'cr'
>add/ISCL_xxx_snn'cr''lf']
Where:
xxx = TX1, TX2, RX1, or RX2 (service channel
designator).
nnn = -20 to +10 in steps of 1 (service channel
level in dBm).
IDR Backward
Alarm Enable
Command:
Response:
Status:
Response:
<add/BW_xxx_nnn'cr'
>add/BW_xxx_nnn'cr''lf']
<add/BW_xxx_'cr'
>add/BW_xxx_nnn'cr''lf']
Where:
xxx = TX1, TX2, TX3, TX4, RX1, RX2, RX3, or
RX4 (backward alarm designator).
nnn = ON or OFF.