SDM-300A Satellite Modem

Revision 6

Specifications

MN/SDM300A.IOM

19–2

Table 19-1. General Specification (Continued)

Parameter

Specification

Forward Error

Correction

Viterbi K = 7: Rate 1/2, 3/4, 7/8, 2/3
Reed-Solomon: Rate 225/205, 126/112, 219/201
IBS: 219/201/4
Turbo: Rate 5/16, 21/44, 1/2, 3/4
Sequential: Rate 1/2, 3/4, 7/8
(Code rates selectable from front panel)

Monitor and Control

Front panel display (16 character by 2 rows), backlit

Filter Mask Types

INTELSAT/EUTELSAT
Closed net (Comtech EF Data)
Closed net (Fairchild compatible), SDM-51 compatible

ESC IDR

IBS
None, field-selectable

Loopback Modes

Baseband (near end and far end)
Interface (near end and far end)
D&I baseband (insert data into drop data out)
IF Loopback (near end)
RF Loopback (far end)

Diagnostic Features

IF Loopback
RF Loopback
Baseband Loopback
Interface Loopback
Fault monitoring (includes current and stored faults)
BER monitoring
Input IF power monitoring
Buffer fill status monitoring
Remote control via serial port