Ncr host, Line module port description copy port parameters, Configuration module port – Verilink 9000 Series (34-00271) Product Manual User Manual

Page 164

Advertising
background image

142

C

HAPTER

8: NCR

NCR Host

Line Module

This field indicates the line module number of the port being displayed. Entering a
different line module number and pressing F10 transfers the screen to the same
port on the new line module.

Port

The port field indicates the number of the displayed port. A different port may be
selected by entering its number in this field and pressing F10.

Description

This is a free-form field intended to describe the location or department this port
services.

Copy Port Parameters

The three fields on this line work together to allow copying an existing port
configuration to the current port.

Configuration.

Enter the configuration number where the stations to be copied

reside.

Module.

This parameter represents the line module number in the source unit.

Port.

Enter the port number where the source stations reside.

After these fields have been filled, press F10. This re-displays the port using the
copied values.

TXPORT INTELLINET Configuration Program

Configuration 1000

NCR Host Port Parameters

Line Module [01] Port [3] Description [NCR Host ]

Copy Port Parameters from Configuration [ ] Module [ ] Port [ ]

Baud Rate [ 9600] Bits per Character (7/8) [7]

Parity (O/E/N) [E] Message Buffer [4096]

Interface (A/V) [A]

Termination (DCE/DTE) (9200 only) [DCE]

Trailing Pads (0/1/2) [0]

Turnaround Delay (ms) [ 0]

RTS/CTS Control (O/D/F) [D]

Poll Timer (sec) [ 60]

Input Timer (ms) [1600]

Host Name [NCR ]

Backup Host Name [ ]

ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next

Figure 8-4 NCR Host Screen