Ipx static route table parameters – Verilink 9000 Series (34-00271) Product Manual User Manual

Page 348

Advertising
background image

326

C

HAPTER

19: IPX R

OUTER

IPX Static Route

Table Parameters

To add or modify an IPX static route from the main IPX Static Route menu, press
F3 or F2 and Figure 19-4 appears. To list all configured IPX static routes, press
F4. The Static Route number must be unique and range from 1 to 255. The
Associated Circuit Number must be set to a Configured Circuit in the circuit menu.

Defaults are shown underlined.

Line Module

This field indicates the line module number of the port currently displayed.
Entering a different line module number and pressing F10 transfers the screen to
the same port on the new line module.

Static Route Number

This field represents the entry number of that static route. It should never be
changed.

Enable This Static Route

This field enables the static route.

Associated Circuit Number

This value must be set to the circuit number used for this Static Route. It ranges
from 1 to 255. The default value is 1.

TXPORT INTELLINET Configuration Program

Configuration

Add IPX Static Route

Line Module

Static Route number [001] Enable this Static Route [Y]

Associated Circuit Number [001]

IPX Network Address of Destination [00000000]

IPX Node Address of Next Hop [000000000000]

IPX Hops To Destination [ 1]

IPX Number of Tics to Destination [ 100]

Figure 19-6 IPX Static Route Table Parameters Screen

Advertising