Ip static route table parameters – Verilink 9000 Series (34-00271) Product Manual User Manual

Page 327

Advertising
background image

NMCS Screens

305

IP Static Route

Table Parameters

There are some situation where a router cannot learn a route using ordinary means
like RIP or OSPF. This may arise again for security matters. Then it is possible to
add a route to the route table of a router.

Again, this menu is always associated with a circuit. To add or modify a static
route from the main static route menu, press F3 or F2 and Figure 18-8 appears. To
list all configured static routes, press F4.

Defaults are shown underlined.

Line Module

This field indicates the line module number of the port currently displayed.
Entering a different line module number and pressing F10 transfers the screen to
the same port on the new line module.

Static Route Number

Each Static Route Number must be unique and range from 1 to 255. The Static
Route Number must be associated with a Circuit Number configured in the Circuit
Configuration menu shown in IP Router Parameters Screen on page 291.

Enable This Static Route

This option enables this route entry. The default value is Yes.

TXPORT INTELLINET Configuration Program

Configuration

ADD Static Route menu

Line Module

Static Route number [001] Enable this Static Route [Y]

Associated Circuit Number [001]

IP Address Of Target [ ].[ ].[ ].[ ]

IP Mask Of Target [ ].[ ].[ ].[ ]

IP Address Of Next Hop [ ].[ ].[ ].[ ]

Static Route cost [ 178]

F1=Hlp F2=Mod F3=Add F4=List F5=Clr F6=DelAll F7=Copy F8=Jmp F9=Prev F10=Next

Figure 18-8 IP Static Route Table Parameters Screen