Test Menu

389

Test Menu

The Test Menu allows pinging. The counter determines the number of pings,
ranging from 1 to 30. Setting the Counter field to 0 lets ping run continuously. The
timer determines the maximum number of seconds allowed for and between each
ping. If a ping is not successful on or before the Timer field value, the device
displays a time out. If the ping is received late (after a timeout) the timer
automatically increments by one second. The maximum value of the timer is 10
seconds. If a single ping is not completed in 10 seconds, the unit times out. The
results of the ping are the target unit; status of the data; and minimum, maximum,
and average times in milliseconds. To end a ping at any point, press Escape.

TEST MENU

---------

BERT TEST

(B)

LOOPBACK (L)

PING TEST

(P)

MAIN MENU

(M)

Enter choice: p

ENTER UNIT # ( xxx ): 000

Counter : 5 Timer : 1 Unit : 000

S - Start ping

C - Change counter value

T - Change timer value

U - Change unit

M - Main menu

Statistics Menu

The Statistics Menu reports statistical information about ports and stations. This
information includes response times, characters transmitted and received, and
messages transmitted and received. Using this information can help in locating
problem devices and performance problems. When 3 (STATISTICS MENU) is
selected from the main menu, the following screen is displayed.

STATISTICS MENU

----------------------------

C - Display line module statistic

L - Display link statistic

S - Display station statistic

B - Bridge statistic menu

R - Reset link statistics

Z - Reset station statistics

M - Main menu

Enter choice :