62

C

HAPTER

4: NMCS

Line Module

Parameters

Line Module parameters describes the common parameters used by this unit. An
example of the Line Module Parameters screen is shown in Figure 4-13.

Line Module

This field indicates which line module the defined parameters apply to. Entering
another line module number and pressing F10 takes the message screen to the new
line module.

Copy Line Module Parameters from Configuration

When copying line module parameters, both fields on this line must be filled in.
First enter the number of the configuration to copy from. This may be the current
configuration or a different one. The second field is the number of the line module
to copy from. Pressing F10 initiates the copy.

Serial number

This is an optional field used to track the serial number of the circuit board that is
represented by this line module.

Network Host

This parameter is no longer used.

Connect Timeout

When a station attempts to connect to a destination, it waits for the amount of time
specified here before declaring a connection failure. This field rarely needs to be
changed and should be left at its default value.

TXPORT INTELLINET Configuration Program

Configuration 1000

Line Module Parameters

Line Module [01]

Copy Line Module Parameters from Configuration [ ] Line Module [ ]

Serial Number [ ] Network Host [NMCS ]

Connect Timeout (sec) [ 30] Task to Task Timeout (sec) [ 15]

Task to Terminal/Host Timeout (sec) [ 30]

Connect Command (6 char) [CONN ] Disconnect Command (6 char) [DISC ]

Send Command (6 char) [SEND ] Reserve Command (6 char) [RESV ]

Disconnect Message (24 char) [DISCONNECT ]

Port Type Description Port Type Description

1 [01] P/S Terminal 2 [13] Frame Relay

3 [99] Undefined 4 [99] Undefined

D [00] Console L [19] Ethernet Bridge

Line Module Type [9000] Firmware Version [6.08 ]

ESC=Main Menu F1=Help F5=Clear F7=Redisplay F8=Jump F9=Previous F10=Next

Figure 4-13 Line Module Parameters Screen