To go back to the main menu, enter M. To edit or display the configuration, enter
E. If E was entered, the following is displayed.

ENTER TARGET (unit.linemodule -> xxx.yy) :

As indicated by the display, enter the unit number (xxx), a period (.) and a line
module number (yy). The default unit number is 000. The line module number is
01. After initializing the unit, a display similar to the following is shown.

Loading configuration...

DISPLAY/MODIFY CONFIGURATION

----------------------------

PDC9100 UNIT # 000 LINE MODULE # 01 FIRMWARE : 3.0100

Line module type : MASTER

Port

Baud

Bits

Parity

Link

type

rate

/char

inter

----

----

-----

------

------

PORT #1

P/S TERMINAL

38400

7

EVEN

RS-232 Async

PORT #2

PORT #D

CONSOLE

AUTO

7

EVEN

PORT #L

(? for help) >

This display gives a summary of how the five ports on this line module are
configured. If a ? (question mark) is entered, the displayed list of responses below
is shown.

? - Help menu

L - Line module parameters

P - Port parameters

N - Name table

I - Internetwork Protocols configuration

D - Default configuration

M - Default NMCS Configuration

C - Clear configuration

S - Save configuration

X - Exit edition

(? for help) >

Help menu

? redisplays the help menu.
D creates a default configuration which is normally only used for testing.
C clears the existing configuration.
X returns the display to the configuration menu, shown earlier in the paragraph. If
any of the above letters are typed, typing Y confirms the choice.
S saves the configuration just entered or changed to the non-volatile flash memory.
N shows the Name Table for this Line Module. It is normally used by TXPORT
technical personnel as a troubleshooting tool.
L is explained on page 383.
P is explained on page 386.
I is explained on page 388.