Line Impedance:
balanced 100
Ω
(± 5%)
Input Signal:
DS1, +1 to -27 dB (ALBO)
Output Signal:
3.0 V (±15%) base-peak into 100
Ω
Line Build Out:
0, -7.5, -15, and -22.5 dB attenuation
Line Protection:
1000 V lightning, input and output
Jitter Control:
per TR62411 and T1.403
Pulse Density:
per TR62411
Industry Standards.
FCC Compliance:
Part 15 Subpart B, Class A, Part 68
U.S. Safety:
1950 3
rd
Edition
Canadian Safety:
C22.2 No. 950-95
IC:
CS-03, Issue 8
ANSI T1.403:
1989
TR54016:
April 1988
TR62411:
December 1990
LAN Interface
Connection:
10 Base -T, RJ-48
Ethernet:
ISO/IEC 802-3
Protocols
IBM:
SNA/SDLC, SNA/RJE, 3780 BSC, 3270 BSC, 5250,
NCR:
Poll/Select, UNIX X.25
Unisys:
Poll/Select, T27 emulation, Uniscope
TTY:
Host, Terminal, Printer
The protocol suite supported must be specified when ordering.
Logical Addresses
Supported:
512 (9101, 9111, and 9211) 1500 (6400 and 6800)
IP Routing Protocols: IP, RIP, RIP-II, and OSPF
IPX Routing
Protocols:
IPX, RIP, SAP, and NLSP
LAN Protocols:
Novell IPX, TCP/IP, NetBios, DECNet, XNS,
Banyan VINES, AppleTalk
WAN Protocols:
Frame Relay, X.25, Full-Duplex Multi-Drop, IP PAD
WAN Media:
Analog and digital leased lines, dial lines, Switched 56,
ISDN, microwave links, satellite links
Filtering:
Station filtering and protocol filtering
Bridging Protocols: Transparent bridging with full IEEE 802.1d support