Drive Parameters

A1 Initialization

The initialization group contains parameters associated with initial setup of the Drive. Parameters involving the display

language, access levels, initialization and password are located in this group.

A1-00 Select Language (Optional LCD keypad only)

The setting of parameter A1-00 determines which international language the Drive will use to display non-numerical text. The
A1-00 parameter will not be changed by an Initialization of the Drive (A1-03= “1110: User Initialize”, “2220: 2-Wire Initial”, or
“3330: 3-Wire Initial”).

If the Drive is accidentally set to a language unfamiliar to the operator, locating the parameter to change the operator language
can be done by performing the following:

1. Press the MENU key until the “-ADV-” MENU is shown in the upper left corner of the digital operator.
2. Press the DATA/ENTER key to enter the programming menu. The first parameter shown is A1-00 (Select Language).
3. Press the DATA/ENTER key again and use the INCREASE and DECREASE arrow keys to choose the preferred language

from the list below:

0 : English
1 : Japanese
2 : Deutsch (German)
3 : Francais (French)
4 : Italiano (Italian)
5 : Español (Spanish)
6 : Portuguės (Portuguese)

A1-01 Access Level Selection

A1-01 can be used to allow access to and permission to change all Drive parameters. If the Drive is programmed for Operation
Only (A1-01= “0: Operation Only”), then only the OPERATION and the PROGRAMMING menus are accessible. Within the
PROGRAMMING menu only parameters A1-01 and A1-04 are adjustable.

Setting

Description

0

English (factory default)

1

Japanese

2

Deutsch

3

Francais

4

Italiano

5

Espanol

6

Portugues

Setting

Description

0

Operation Only

1

User Level

2

Advanced Level (factory default)