Auto-tuning faults, Table 6.6 auto-tuning displays and processing, Diagnostic & troubleshooting 6 - 17 – Yaskawa E7L Drive Bypass User Manual

Page 189

Advertising
background image

Diagnostic & Troubleshooting 6 - 17

Auto-Tuning Faults

Auto-tuning faults are shown below. When the following faults are detected, the fault is displayed on the digital operator and
the motor coasts to a stop during operation. The fault contact is not activated.

Table 6.6 Auto-Tuning Displays and Processing

Digital Operator Display

Probable Cause

Corrective Action

Er - 01

Fault

• There is an error in the data input

for autotuning.

• There is an error in the relationship

between the motor output and the
motor rated current.

• Check input data.
• Check Drive and motor capacity.
• Check motor rated current.

Er - 02

Minor Fault

A minor fault is detected during
auto-tuning.

• Check input data.
• Check wirings and around the

machine.

• Check the load.

Er - 03

STOP key

The STOP key is pressed during
auto-tuning, and the auto-tuning is
interrupted.

Er - 04

Resistance

Auto-tuning is not completed within
the specified time.
The auto-tuning result became other
than the parameter set range.

• Check input data.
• Check motor wiring.
• If a motor and a machine are

connected, disconnect the motor
from the machine.

Er - 12

I-det. Circuit

• Current flow exceeded the motor

rated current.

• Current detection value symbol

was reversed.

• Any of U/TI, V/T2, and W/T3 has

open-phase.

• Check current detection circuit,

wiring and mounting procedure.

Er - 13

Leakage Inductance Fault

Auto-tuning did not finish within the
set time.
Tuning result became other than the
parameter setting range.

• Check motor wiring.

End - 3

Data Invalid

Rated current set value is set too
high.

• Check input data (especially,

motor output current and motor
rated current value).

Advertising