480 vac, Table c.2 480vac drive and bypass specifications, Table c.2 480vac drive specifications (continued) – Yaskawa E7L Drive Bypass User Manual

Page 251: Specifications c - 3

Advertising
background image

Specifications C - 3

480 VAC

Table C.2 480VAC Drive and Bypass Specifications

Bypass Model Number E7L_ *

B001

B002

B003

B004

B007

B011

B014

Motor HP (460V)

0.5/0.75

1

1.5/2

3

5

7.5

10

Bypass rated output current (A)

1.6

2.1

3.4

4.8

7.6

11

14

Drive Model Number CIMR-E7U

42P2

42P2

42P2

42P2

43P7

45P5

47P5

Drive rated output capacity (kVA)

1.4

1.6

2.8

4.0

5.8

9.5

13.0

Drive rated output current (A)

1.8

2.1

3.7

5.3

7.6

12.5

17.0

Drive max. output voltage (V)

3-phase; 380, 400, 415, 440, 460, or 480VAC (Proportional to input voltage.)

Drive max. output frequency (Hz)

120 Hz

Rated voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460 or 480VAC, 50/60 Hz

Rated input current (A)

2.2

2.5

4.4

6.4

9.0

15

20

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Measures for
power supply
harmonics

DC Reactor

Optional

12-pulse
Rectification

Not possible

Table C.2 480VAC Drive Specifications (Continued)

Bypass Model Number E7L_ *

B021

B027

B034

B040

B052

B065

B077

Motor HP (460V)

15

20

25

30

40

50

60

Bypass rated output current (A)

21

27

34

40

52

65

77

Drive Model Number CIMR-E7U

4009

4011

4015

4018

4024

4030

4037

Drive rated output capacity (kVA)

17.0

21.0

26.0

30.0

41.0

51.0

59.0

Drive rated output current (A)

21.0

27.0

34.0

40.0

52.0

67.2

77.0

Drive max. output voltage (V)

3-phase, 380, 400, 415, 440, 460 or 480VAC (Proportional to input voltage)

Drive max. output frequency (Hz)

120 Hz

Max. voltage (V)
Rated frequency (Hz)

3-phase, 380, 400, 415, 440, 460, or 480VAC, 50/60 Hz

Rated input current (A)

26

33

40

48

57

74

85

Allowable voltage fluctuation

+ 10%, - 15%

Allowable frequency fluctuation

±5%

Measures for power
supply harmonics

DC Reactor

Optional

Built-in

12-Pulse
Rectification

Not possible

Possible

Note: The maximum applicable motor output is given for a standard 4-pole motor. When selecting the actual motor and Drive, be sure that the Bypass

and Drive's rated output current is equal to, or greater than, the motor's rated current.

A 3-wire phase-shifting transformer is required on the power supply for 12-pulse rectification.

Po

wer s

uppl

y characteris

tics

Power

s

upp

ly charact

eris

ti

cs

Cont

rol

c

harac

ter

is

tic

s

C

on

tr

ol

ch

ar

ac

te

ri

sti

cs