Chapter 6, Diagnostics & troubleshooting, Chapter 6 diagnostics & troubleshooting – Yaskawa E7L Drive Bypass User Manual

Page 173

Advertising
background image

Diagnostic & Troubleshooting 6 - 1

Chapter 6

Diagnostics & Troubleshooting

This chapter describes diagnostics and troubleshooting for the Drive and Bypass.

E7L Bypass PCB and H/O/A Control Panel Diagnostics ................ 2

Introduction ................................................................................ 2
Specifications.............................................................................. 2
Set Up for Maintenance Mode.................................................... 2
Testing ........................................................................................ 3

Drive Diagnostics ........................................................................... 6

Fault Detection .......................................................................... 7
Alarm Detection ....................................................................... 13
Operator Programming Errors (OPE) ...................................... 16
Auto-Tuning Faults .................................................................. 17
Digital Operator COPY Function Faults ................................... 18

Drive Troubleshooting .................................................................. 19

If Parameter Cannot Be Set .................................................... 19
If the Motor Does Not Operate ................................................ 20
The Direction of the Motor Rotation is Reversed ..................... 21
If the Motor Does Not Put Out Torque or

If Acceleration is Slow ............................................................. 21
If the Motor Operates at a Higher Speed

Than the Speed Command ...................................................... 21
If the Motor Overheats ............................................................. 22
If Peripheral Devices Like PLCs or Others are Influenced by
Starting or Running Drive ......................................................... 22
If a Stand Alone Ground Fault Interrupter Operates When

the Drive is Run ....................................................................... 23
If There is Mechanical Vibration .............................................. 23
If the Motor Rotates Even When Drive Output is Stopped ....... 24
If Zero Volts is Detected When a Motor is Started, or Stalls .... 24
If Output Frequency Does Not Rise to Frequency Reference . 24

Drive Main Circuit Test Procedure ................................................ 25
Drive Date Stamp Information ...................................................... 29

Advertising