Maintenance 7 - 9

Fig 7.7 Drive Bottom Mounting Bracket

Fig 7.8 Back Panel with Mounting Ring

To free the Drive, remove the bolts from the Drive mounting brackets (remove the bottom first). When free, pull the Drive

through the front of the Bypass enclosure by guiding the heat sink back through the opening in the back panel.

With the Drive out of the Bypass assembly, remove the mounting brackets from the old Drive by removing the bolts affixing

the mounting brackets to the Drive. Attach the mounting brackets to the new Drive using the bolts from the old Drive.

Installing the Replacement Drive

Place the new Drive into the Bypass by sliding the heat sink through the opening in the rear of the Bypass enclosure. Line up

the holes on the mounting brackets with the holes in the back panel of the Bypass assembly. Use the mounting bolts

previously removed to re-affix the Drive to the Bypass back panel.

When the new Drive has been mounted in the Bypass enclosure, reconnect all power wiring and verify by checking the Bypass

schematic.

Re-mount the control ribbon cable to the Drive by sliding the ribbon cable connector into Drive control PCB connector (CN8).

Re-mount any option card, and re-connect all wiring from the option card to the Drive. Be sure to re-connect the ground wire

to the Drive.

With the Drive replacement complete, return power to the Bypass unit. Locate the start-up procedure for the Drive and Bypass

in Chapter 4 and follow the complete start-up procedure.

Drive Bottom Bracket

Bypass Enclosure

Back Panel

Mounting

Ring