Table a.1 parameter list, Parameter no, Parameter name – Yaskawa E7L Drive Bypass User Manual

Page 214: Lcd digital operator display, Description, Setting range, Factory setting, Menu, Location, Initialization

Advertising
background image

Parameters A - 2

Parameter List

Table A.1 Parameter List

Parameter

No.

Parameter Name

LCD Digital Operator

Display

Description

Setting

Range

Factory

Setting

Menu

Location

Initialization

A1-00

Language Selection
Select Language

Language selection for digital operator display
0: English
2: Deutsch
3: Francais
4: Italiano
5: Espanol
6: Portugues
*Not returned to factory setting by initialization

0 to 6

0

Programming

A1-01

Access Level Selection
Access Level

This setting determines which parameters are accessible.
0: Operation Only
1: User Level
2: Advanced Level

0 to 2

2

Programming

A1-03

Initialize Parameters
Init Parameters

Used to return all parameters to their factory or user setting.
0: No Initialize
1110: User Initialize (The user must set their own parameter
default values and then parameter o2-03 must be set to “1” to save
them. If the parameter values are changed after o2-03 is set to “1”,
the user default values can be restored by setting A1-03 to 1110)
2220: 2-Wire Initial
3330: 3-Wire Initial

0 to

3330

0

Programming

A1-04

Password 1
Enter Password

When the value set into A1-04 does NOT match the value set into
A1-05, parameters A1-01 thru A1-03 and A2-32 cannot be
changed. All other parameters determined by A1-01 can be
changed. Parameter A1-05 can be accessed by displaying
parameter A1-04, then press and hold the RESET key along with
the MENU key simultaneously.

0 to 9999

0

Programming

A1-05

Password 2
Select Password

0 to 9999

0

Programming

User Parameters

A2-01

User Parameter 1
User Param 1

Selects the parameters to be available in the User Access Level
(A1-01 = 1). These are the only parameters accessible for the user
level. These parameters are not related to the User Initialize
function.

b1-01

to

o3-02

Programming

A2-02

User Parameter 2
User Param 2

Programming

A2-03

User Parameter 3
User Param 3

Programming

A2-04

User Parameter 4
User Param 4

Programming

A2-05

User Parameter 5
User Param 5

Programming

A2-06

User Parameter 6
User Param 6

Programming

Denotes that parameter can be changed when the drive is running.

Advertising