Programming 5 - 15

2:DCInj to Stop: When the Run command is removed, the Drive will Baseblock (turn off its output) for the Minimum Base-

block Time (L2-03). Once the Minimum Baseblock Time has expired, the Drive will inject DC current into the motor wind-
ings to lock the motor shaft. The stopping time will be reduced as compared to Coast to Stop. The level of DC Injection
current is set by parameter b2-02 (50% Default). The DC Injection brake time is determined by the set value in b2-04 and
the output frequency at the time the Run command is removed.

Fig 5.4 DC Injection Braking to Stop

3:Coast w/Timer: When the Run command is removed, the Drive will turn off its output and the motor will coast to a stop. If

a Run command is input before time T (Operation Wait Time) expires, the Drive will not run and the Run command will
need to be cycled before operation can occur. The time T (Operation Wait Time) is determined by the output frequency
when the Run command is removed and the active deceleration time (C1-02).

Fig 5.5 Coast to Stop with Timer

IMPORTANT

If an overcurrent (OC) fault occurs during DCInj to Stop, lengthen the Minimum Baseblock Time (L2-03)
until the fault no longer occurs.

04)

-

(E1

Frequency

Maximum

Frequency

Output

10

04)

-

(b2

Time

Brake

Injection

DC

×

×

=

ON

OFF

Run Command

Output Frequency

Drive Output Voltage Interrupted

DC Injection Brake

DC Injection Brake Time

Minimum Baseblock

Time (L2-03)

100 %

0 %

D

C

In

je

ct

io

n Brak

e T

im

e

b2-04 x 10

b2-04

10%

100% (Maximum

Output Frequency)

b2-04

(CLOSED)

(OPEN)

Run Command

Output Frequency

Drive Output

Voltage

Interrupted

OFF

ON

Timer Value T

(C1-02)

100 %

0 %

Operat

io

n W

ai

t T

im

e (T

)

Deceleration

Time (C1-02)

Minimum

Baseblock

Time (L2-03)

Minimum

Output

Frequency

100% (Maximum

Output

Frequency)

Output Frequency at Stop Command Input

Ignored

Run Command

Timer Value T

(OPEN)

(CLOSED)