2 reset controller, 3 shutdown controller, 4 clock generator – Rainbow Electronics AT91CAP9S250A User Manual

Page 29

Advertising
background image

29

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

9.2

Reset Controller

• Based on two Power-on-Reset cells

– One on VDDBU and one on VDDCORE

• Status of the last reset

– Either general reset (VDDBU rising), wake-up reset (VDDCORE rising), software

reset, user reset or watchdog reset

• Controls the internal resets and the NRST pin output

– Allows shaping a reset signal for the external devices

9.3

Shutdown Controller

• Shutdown and Wake-Up logic

– Software programmable assertion of the SHDN pin

– Deassertion Programmable on a WKUP pin level change or on alarm

9.4

Clock Generator

• Embeds the low power 32,768 Hz Slow Clock Oscillator

– Provides the permanent Slow Clock SLCK to the system

• Embeds the Main Oscillator

– Oscillator bypass feature

– Supports 8 to 16 MHz crystals

– 12 MHz crystal is required for USB High-Speed Device

• Embeds 2 PLLs

– Output 80 to 200 MHz clocks

– Integrates an input divider to increase output accuracy

– 1 MHz minimum input frequency

Figure 9-2.

Clock Generator Block Diagram

Power

Management

Controller

XIN

XOUT

PLLRCA

Slow Clock
SLCK

Main Clock
MAINCK

PLLA Clock
PLLACK

Control

Status

PLL and
Divider B

PLLRCB

PLLB Clock
PLLBCK

XIN32

XOUT32

Slow Clock

Oscillator

Main

Oscillator

PLL and
Divider A

Clock Generator